FilmArray® GI Control Panel M238

(2 reviews) Write a Review
SKU:
M238
Size:
12 x 200 µL
DataSheet:
Download PDF
  • FilmArray® GI Control Panel M238
  • BioFire FilmArray
Select Currency //575.00

 Select your currency from the header

Description

MMQCI FilmArray® GI Control Panel M238

Part Number: M238

Kit Contains: 12 tubes x 200 µL

6 each of M2393718 & M2402818

FilmArray® GI Control Panel M238 DataSheet

INTENDED USE:

The FilmArray® GI Control Panel M238 is intended for in vitro use as a quality control to monitor the detection and identification of multiple gastrointestinal pathogens as performed by the FilmArray® Gastrointestinal (GI) Panel assay on the FilmArray® instrument. Detection of the viruses, bacteria and protozoa listed in Table 1 is an important aid to the diagnosis of gastrointestinal illness.

FilmArray® GI Control Panel M238 cannot be cloned, sold, or transferred without the explicit written consent of MMQCI.

PRODUCT SUMMARY and PRINCIPLE:

FilmArray® GI Control Panel M238 is comprised of synthetic RNA suspended in a non-infectious solution of buffers, preservatives and stabilizers.

Best practice is to establish a quality control program for every assay performed by the laboratory.1, 2 Routine use of quality controls that are consistent lot to lot assists the laboratory in identifying shifts, trends, and increased frequency of random errors caused by variations in the test system, such as failing reagents. Early investigation can prevent failed assay runs.

COMPOSITION:

The FilmArray® GI Control Panel M238 is comprised of 12 tubes, 200µL each, containing synthetic RNA suspended in a non-infectious solution of buffers, preservatives and stabilizers. Table 1 lists the pathogens that are monitored by the FilmArray® GI Control Panel M238 when tested by the FilmArray® Gastrointestinal Panel on the FilmArray® instrument.

STORAGE and STABILITY:

FilmArray® GI Control Panel M238 should be stored frozen (-25°C to -15°C). Unopened FilmArray® GI Control Panel M238 is stable through the expiration date printed on the kit label when continuously stored frozen. FilmArray® GI Control M239 and FilmArray® GI Control M240 are for single use. Discard after use according to your local and federal regulations.

INSTRUCTIONS FOR USE:

  1. Allow the control to be tested to come to room temperature (18° – 25°C).
  2. Use the control as provided. DO NOT DILUTE.
  3. Prepare and hydrate a pouch according to FilmArray®
  4. Immediately before use, mix the control by briefly vortexing the tube for 3 – 5 seconds and then shake the tube down firmly to remove any droplets caught in the cap.
  5. Using the FilmArray® transfer pipette, draw up the control to 2nd line.
  6. Analyze the control as you would a patient sample by adding the control to the FilmArray® Sample
  7. Discard after use according to your local and federal

PRECAUTIONS and WARNINGS:

  • Do not
  • This product is intended for in vitro analytical testing and is provided for Research Use Only, not for use in diagnostic
  • This product does not contain any biological material of human or animal

EXPECTED VALUES:

The laboratory should follow Good Laboratory Practice (GLP) and establish its own performance characteristics for FilmArray® GI Control Panel M238 in demonstrating adequate system performance. Recoveries may vary depending on instrumentation, reagents and systematic or random errors. The expected results when the controls are analyzed are listed in Table 1.

Table 1: FilmArray® Result Summary Interpretation

Assay

M2393718 Call

M2402818 Call

Bacteria

Campylobacter

Not Detected

Detected

Clostridium difficile toxin A/B

Detected

Not Detected

Plesiomonas shigelloides

Detected

Not Detected

Salmonella

Not Detected

Detected

Vibrio

Detected

Not Detected

Vibrio cholerae

Detected

Not Detected

Yersinia enterocolitica

Detected

Not Detected

Diarrheagenic E.coli/Shigella

Enteroaggregative E. coli (EAEC)

Detected

Not Detected

Enteropathogenic E. coli (EPEC)

Ø N/A

Detected

Enterotoxigenic E. coli (ETEC) lt/st

Not Detected

Detected

Shiga-like toxin-producing E. coli

(STEC) stx1/stx2

Detected

Not Detected

E. coli O157

Detected

Ø N/A

Shigella/Enteroinvasive E. coli (EIEC)

Detected

Not Detected

Parasites

Cryptosporidium

Detected

Not Detected

Cyclospora cayetanensis

Not Detected

Detected

Entamoeba histolytica

Not Detected

Detected

Giardia lamblia

Not Detected

Detected

Viruses

Adenovirus F 40/41

Detected

Not Detected

Astrovirus

Not Detected

Detected

Norovirus GI/GII

Not Detected

Detected

Rotavirus A

Not Detected

Detected

Sapovirus

Detected

Not Detected

 

View AllClose

2 Reviews

  • 5
    Fatstest delivery

    Posted by Axel on 7th Jan 2022

    The parcel was delivered before the last date which surprised me so much because mostly a customer usually not get the parcel before the deadline date but after buying a product from this company my stereotype has changed. Thanks!

  • 5
    FilmArray® GI Control Panel M238

    Posted by MMQC on 11th Jun 2021

    The FilmArray® GI Control Panel M238 is intended for in vitro use as a quality control to monitor the detection and identification of multiple gastrointestinal pathogens as performed by the FilmArray® Gastrointestinal (GI) Panel assay on the FilmArray® instrument.

View AllClose