News
GeneXpert® Testing Quality Controls
Thrombotic
Risk:
Xpert FII & FV HETCatalog
No.: G108-2H; 2 bottles of Heterozygous x 0.5 mL
Xpert FII & FV NOR/MUT ControlCatalog
No.: G11601; 2 bottles each of Normal & Mutant x 0.5 mL
Xpert FII & FV Genotype Panel G109Catalog
No.: G109; 2 bottles of Heterozygous & 1 bottle each of Normal & Mutant
x 0.5 mLInfectious
Disease:
INTROL® TB Panel M114Catalog
No.: M114-5; 5 bottles each of TBWT-04, TBMDR1-04 & TBNEG x 1.0 mLCatalog
No.: M114-10; 10 bottles each
…
14th Jun 2021
MMQCI Infectious Disease Testing BioFire® FilmArray® Quality Controls
Blood Culture ID:FilmArray BCID Control Panel M235 v1.1Catalog
No.: M235v1.1Kit
Contains: 12 tubes x 200 µL; 6 each of
Positive controls & Negative controlsFilmArray BCID2 Control Panel M416Catalog
No.: M416Kit
Contains: 12 tubes x 200 µL; 6 each of
Positive controls & Negative controls
Ebola: FilmArray Ebola Control Panel M251Catalog
No.: M251Kit
Contains: 12 tubes x 200 µL; 6 each of
Positive controls & Negative controls
Gastrointestinal:
FilmArray GI Control P
…
14th Jun 2021
Quality Controls for M. tuberculosis Testing
INTROL® TB Panel M110Drug Resistance Mutations found in INTROL TB Panel M110:
Catalog
No: M110
4 bottles x 3 mL
1 bottle each:
TBWT-04, TBMDR1-04, TBMDR2-04 & TBNEG
Control
Drug Resistance Mutation
INTROL® TBWT-04
Wild type
rpoB: F505L, L511P, D516V, H526Y
INTROL® TBMDR1-04
inhA: -15
katG: S315T (AGC> ACC)
rpoB: S522L, H526D, S531L
INTRO
…
13th Jun 2021
InstantBlue SDS-Page Gel Staining
Easy,
sensitive and fast protein gel staining with Expedeon InstantBlue dye reagentThe
results are visible within 15 minutes only1.What is the formulation of the Instant
blue reagent?Instant Blue stain is a ready-to-use reagent for fast and sensitive
protein staining on electrophoresis polyacrylamide gels. The results can be
obtained within a few minutes and no procedures of washing, fixing or
de-staining are needed.The reagent contains Coomassie dye, phosphoric acid, ethanol and
solubili
…
9th Jun 2021
Quality Control Materials for use with FilmArray® Panels
IntroductionThe Clinical Laboratory
Improvement Amendments (CLIA), passed in1988,
establishes quality standards for all laboratory testing to ensure the accuracy and reliability of patient test
results, regardless of where the testis
performed. CLIA regulations require a laboratory to have quality control(QC) procedures to monitor the accuracy and precision of
the complete testing process.This document
provides a listing of QC materials
that have been tested at BioFire and are
compa
…
8th Jun 2021