eSensor® XT-8 RVP Control Panel

(2 reviews) Write a Review
SKU:
M243
Size:
12 x 200 µL
DataSheet:
Download PDF
  • eSensor® XT-8 RVP Control Panel
  • eSensor XT-8 GenMark
€728.00

 Select your currency from the header

Description

MMQCI eSensor® XT-8 RVP Control Panel

Part Number: M243

Kit Contains:12 tubes x 200µL

6 each of M244 & M245

eSensor® XT-8 RVP Control Panel DataSheet

INTENDED USE:

The eSensor® XT-8 RVP Control Panel is intended for in vitro use as a quality control to monitor the detection and identification of multiple respiratory viral nucleic acids in nasopharyngeal swabs (NPS) obtained from individuals exhibiting symptoms of respiratory infections when tested by the GenMark Dx eSensor® Respiratory Viral Panel (RVP) Assay on the eSensor® XT-8 instrument.

eSensor® XT-8 RVP Control Panel cannot be cloned, sold, or transferred without the explicit written consent of MMQCI.

PRODUCT SUMMARY and PRINCIPLE:

eSensor® XT-8 RVP Control Panel is synthetic RNA suspended in a non-infectious solution of buffers, preservatives and stabilizers.

Best practice is to establish a quality control program for every assay performed by the laboratory.1, 2 Routine use of quality controls that are consistent lot to lot assists the laboratory in identifying shifts, trends, and increased frequency of random errors caused by variations in the test system, such as failing reagents. Early investigation can prevent failed assay runs.

COMPOSITION:

The eSensor® XT-8 RVP Control Panel is comprised of 12 tubes of synthetic RNA suspended in a non-infectious solution of buffers, preservatives and stabilizers. Table 1 lists the pathogens that are monitored by the eSensor® XT-8 RVP Control Panel when tested by the GenMark eSensor® Respiratory Viral Panel (RVP) Assay on the eSensor® XT-8 instrument.

STORAGE and STABILITY:

eSensor® XT-8 RVP Control Panel should be stored frozen (-25°C to - 15°C). Unopened eSensor® XT-8 RVP Control Panel material is stable through the expiration date printed on the kit label when continuously stored frozen. eSensor® XT-8 RVP Control M244 and eSensor® XT-8 RVP Control M245 are for single use. Discard after use according to your local and federal regulations.

INSTRUCTIONS FOR USE:

  1. Allow the control to be tested to come to room temperature (18° – 25°C).
  2. Immediately before use, thoroughly mix the control by flicking the tube several times, followed by a quick vortex for 3-5 seconds and then shake down or tap on bench to remove any droplets remaining on
  3. Extract the control in the same manner as a patient sample. Use the recommended sample volume of 200µL and elution volume of 60µL.

Note: Prepare the GenMark Dx® supplied tube of Bacteriophage MS2 (IC) according to manufacturer’s instructions and add 10µL of IC to the bottom of easyMAG® disposable well (or bottom of disposable tube used in ‘Generic’ Extractions). Add 200µL of well-mixed control to the disposable well/tube containing the 10µL of IC. Mix and extract according to manufacturer’s recommendations and elute in 60µL.

  1. Analyze the extracted control with GenMark eSensor® Respiratory Viral Panel (RVP) Assay as you would a patient sample, being sure to thoroughly mix the extract with a quick 3-5 second vortex immediately before
  2. Discard after use according to your local and federal

PRECAUTIONS and WARNINGS:

  • Use eSensor® XT-8 RVP Control Panel with GenMark Dx eSensor® Respiratory Viral Panel (RVP) Assay
  • This product does not contain any biological material and is not
  • Use the eSensor® XT-8 RVP Control Panel (single use) as

Do not dilute, re-freeze or transfer to another storage tube.

  • The eSensor® XT-8 RVP Control Panel has been tested with the following extraction protocols: bioMérieux NucliSENS® easyMAG® extraction system, Qiagen QIAamp Viral RNA Mini Kit, and Roche MagNA Pure LC Total Nucleic Acid Isolation
  • Due to the sensitivity of the eSensor® RVP assay, it is important when handling the eSensor® XT-8 RVP Control Panel to adhere to all precautions to prevent contamination.

EXPECTED VALUES:

The laboratory should follow Good Laboratory Practice (GLP) and establish its own performance characteristics for eSensor® XT-8 RVP Control Panel in demonstrating adequate system performance. Recoveries may vary depending on instrumentation, reagents and systematic or random errors. The expected results when the controls are analyzed are listed in Table 1.

GenMark eSensor® Respiratory Viral Panel (RVP) Result Details Table 1

Targets

M244 Result

M245 Result

Influenza A

Positive

Target not detected

Influenza A H1

Positive

---

Influenza A H3

Positive

---

Influenza A 2009 H1N1

Positive

Target not detected

Influenza B

Target not detected

Positive

RSV A

Positive

Target not detected

RSV B

Target not detected

Positive

PIV 1

Positive

Target not detected

PIV 2

Target not detected

Positive

PIV 3

Target not detected

Positive

PIV4*

Positive

Target not detected

hMPV

Target not detected

Positive

HRV

Target not detected

Positive

Adenovirus B/E

Target not detected

Positive

Adenovirus C

Positive

Target not detected

Cov 229E*

Positive

Target not detected

Cov NL63*

Positive

Target not detected

Cov HKU1*

Target not detected

Positive

Cov OC43*

Target not detected

Positive

* Targets reported only with RUO Assay.

  1. ISO 15189: Medical laboratories – Particular requirements for quality and
  2. CAP Molecular Pathology Checklist; Commission on Laboratory Accreditation, Laboratory Accreditation Program, 20000
View AllClose

2 Reviews

  • 5
    superb packing

    Posted by Ezekiel on 7th Jan 2022

    when got my parcel and opened it I was very glad that they packed their products in such a skilled way that products will remain safe from any damage. Really glad about their superb packaging

  • 5
    eSensor® XT-8 RVP Control Panel

    Posted by MMQC on 11th Jun 2021

    The eSensor® XT-8 RVP Control Panel is intended for in vitro use as a quality control to monitor the detection and identification of respiratory viral and bacterial targets in nasopharyngeal swabs (NPS) obtained from individuals suspected of respiratory tract infections when tested by the GenMark eSensor® XT-8 RVP Test on the GenMark instrument.

View AllClose