FilmArray BCID2 Control Panel M416

(2 reviews) Write a Review
SKU:
M416
Size:
12 x 200 µL
DataSheet:
Download PDF
  • FilmArray BCID2 Control Panel M416
  • biofire-filmarray
Select Currency //546.00

 Select your currency from the header

Description

MMQCI FilmArray BCID2 Control Panel M416

Part Number: M416

Kit Contains: 12 tubes x 200μL

6 Positive controls and 6 Negative controls

FilmArray BCID2 Control Panel M416 DataSheet

INTENDED USE:

The FilmArray BCID2 Control Panel M416 is intended for use as an external positive and negative assayed quality control to monitor the performance of in vitro laboratory nucleic acid testing procedures for the qualitative detection of antimicrobial resistance genes: CTX-M, IMP, KPC, mcr-1, mecA/C, mecA/C and MREJ (MRSA), NDM, OXA-48-like,

vanA/B, VIM; Gram positive and Gram negative bacteria: Enterococcus faecalis, Enterococcus faecium, Listeria monocytogenes, Staphylococcus spp., Staphylococcus aureus, Staphylococcus epidermidis, Staphylococcus lugdunensis, Streptococcus spp., Streptococcus agalactiae (Group B), Streptococcus pneumoniae, Streptococcus pyogenes (Group A), Acinetobacter calcoaceticus-baumannii complex, Bacteroides fragilis, Enteric bacteria, Enterobacter cloacae complex, Escherichia coli, Klebsiella aerogenes, Klebsiella oxytoca, Klebsiella pneumoniae group, Proteus spp., Salmonella spp., Serratia marcescens, Haemophilus influenzae, Neisseria meningitidis, Pseudomonas aeruginosa and Stenotrophomonas maltophilia; and yeast pathogens: Candida albicans, Candida auris, Candida glabrata, Candida krusei, Candida parapsilosis, Candida tropicalis, and Cryptococcus neoformans/gattii on the BioFire® Blood Culture Identification 2 (BCID2) Panel on the BioFire FilmArray® systems. This product is not intended to replace manufacturer controls provided with the device.

PRODUCT SUMMARY and PRINCIPLE:

FilmArray BCID2 Control Panel M416 is comprised of 2 controls, FilmArray BCID2 Positive Control and FilmArray BCID2 Negative Control. FilmArray BCID2 Positive Control contains surrogate control material composed of synthetic nucleic acid corresponding to genome segments of the pathogens and antimicrobial resistance markers listed in Table 1. FilmArray BCID2 Negative Control contains no nucleic acid.

Routine use of quality controls that are consistent lot to lot assists the laboratory in identifying shifts, trends, and increased frequency of random errors caused by variations in the test system, such as failing reagents. Early investigation can prevent failed assay runs.

COMPOSITION:

FilmArray BCID2 Control Panel M416 is comprised of 12 tubes, 6 tubes of positive control and 6 tubes of negative control, 200μL each. FilmArray BCID2 Positive Control contains synthetic DNA suspended in a non-infectious solution of buffers, preservatives and stabilizers. FilmArray BCID2 Negative Control contains buffers and preservatives. Table 1 lists the antimicrobial resistance markers and pathogens that are monitored by the FilmArray BCID2 Control Panel M416 when tested by the BioFire BCID2 Panel on the BioFire FilmArray systems.

INSTRUCTIONS FOR USE:

  1. Allow the control to be tested to come to room temperature (18° – 25°C).
  2. Use the control as provided. DO NOT
  3. Immediately before use, mix the control thoroughly by first inverting several times followed by vortexing the tube for 3-5 Tap the tube several times on the bench to remove any control caught in the cap before opening the tube.
  4. Prepare and run a BioFire BCID2 Pouch using the control as you would use a patient specimen, according to BioFire BCID2 Panel Quick Guide or Instructions for
  5. Discard after use according to your local and federal

PRECAUTIONS, WARNINGS and LIMITATIONS:

  • Use the control as provided. Do not dilute or transfer to another
  • This product is intended for in vitro diagnostic use
  • This product is only for use with BioFire BCID2 Panel on the BioFire FilmArray It does not contain the entire genome of the pathogens listed in Table 1.
  • This product is not intended for use as a substitute for the internal controls provided in the BioFire BCID2 Panel assay.
  • This product is red in
  • This product does not contain any biological material of human or animal Universal Precautions are NOT required when handling this product.
  • Quality control materials should be used in accordance with local, state, federal regulations and accreditation
  • FilmArray BCID2 Control Panel M416 cannot be cloned, sold, or transferred without the explicit written consent of MMQCI

STORAGE and STABILITY:

FilmArray BCID2 Control Panel M416 should be stored at 2 - 8°C. Unopened FilmArray BCID2 Control Panel M416 is stable through the expiration date printed on the kit label when consistently stored refrigerated (2° – 8°C). FilmArray BCID2 Positive Control and FilmArray BCID2 Negative Control are for single use. Discard after use according to your local and federal regulations.

EXPECTED VALUES:

Table 1 lists the expected results when the controls are analyzed by BioFire BCID2 Panel. The laboratory should follow Good Laboratory Practice (GLP) and establish its own performance characteristics for FilmArray BCID2 Control Panel M416 in demonstrating adequate system performance.

Table 1: FilmArray BCID2 Positive & Negative Control Result Summary

 

Positive Control

Negative Control

Antimicrobial resistance genes

CTX-M

Detected

N/A

IMP

Detected

N/A

KPC

Detected

N/A

mcr-1

Detected

N/A

mecA/C

Detected

N/A

mecA/C and MREJ (MRSA)

Detected

N/A

NDM

Detected

N/A

OXA-48-like

Detected

N/A

vanA/B

Detected

N/A

VIM

Detected

N/A

Gram Positive Bacteria

Enterococcus faecalis

Detected

Not Detected

Enterococcus faecium

Detected

Not Detected

Listeria monocytogenes

Detected

Not Detected

Staphylococcus spp.

Detected

Not Detected

Staphylococcus aureus

Detected

Not Detected

Staphylococcus epidermidis

Detected

Not Detected

Staphylococcus lugdunensis

Detected

Not Detected

Streptococcus spp.

Detected

Not Detected

Streptococcus agalactiae (Group B)

Detected

Not Detected

Streptococcus pneumoniae

Detected

Not Detected

Streptococcus pyogenes (Group A)

Detected

Not Detected

Gram Negative Bacteria

Acinetobacter calcoaceticus-baumannii complex

Detected

Not Detected

Bacteroides fragilis

Detected

Not Detected

Enteric bacteria

Detected

Not Detected

Enterobacter cloacae complex

Detected

Not Detected

Escherichia coli

Detected

Not Detected

Klebsiella aerogenes

Detected

Not Detected

Klebsiella oxytoca

Detected

Not Detected

Klebsiella pneumoniae group

Detected

Not Detected

Proteus spp.

Detected

Not Detected

Salmonella spp.

Detected

Not Detected

Serratia marcescens

Detected

Not Detected

Haemophilus influenzae

Detected

Not Detected

Neisseria meningitidis

Detected

Not Detected

Pseudomonas aeruginosa

Detected

Not Detected

Stenotrophomonas maltophilia

Detected

Not Detected

Yeast

Candida albicans

Detected

Not Detected

Candida auris

Detected

Not Detected

Candida glabrata

Detected

Not Detected

Candida krusei

Detected

Not Detected

Candida parapsilosis

Detected

Not Detected

Candida tropicalis

Detected

Not Detected

Cryptococcus neoformans/gattii

Detected

Not Detected

 REPRESENTATIVE PERFORMANCE DATA:

Three lots of FilmArray BCID2 Positive Control and three lots of FilmArray BCID2 Negative Control were tested using the BioFire BCID2 Panel assay on BioFire FilmArray systems at 3 external clinical laboratory sites, incorporating 3 unique pouch lots and multiple operators and instruments. A total of 185 external controls were tested over 10 days at each site. Two Controls gave initial Invalid results and three Positive controls gave 1 or more initial false negative results. All produced the correct results upon retesting for an overall correct result rate of 98.4%.

 

Summary of External Results for 3 Control Lots of FilmArray BCID2 Control Panel M416

 

Site

Total Tests

 

Invalid

Correct Positive Control Result

Incorrect Positive Control Result

Percent Correct Positive Control

Correct Negative Control Result

Incorrect Negative Control Result

Percent Correct Negative Control

Total Percent Correct

1

63

2*

30

1

96.8%

30

0

100.0%

98.4%

2

60

0

30

0

100.0%

30

0

100.0%

100.0%

3

62

0

30

2

93.8%

30

0

100.0%

96.8%

All

Sites

185

2

90

3

96.8%

90

0

100.0%

98.4%

* Invalid results were not included in percent correct.

View AllClose

2 Reviews

  • 5

    Colton superior quality

    Posted by Colton on 7th Jan 2022

    The FilmArray BCID2 Control Panel M416 is intended for use as an external positive and negative assayed quality control to monitor the performance of in vitro laboratory nucleic acid testing procedures for the qualitative detection of antimicrobial resistance genes

  • 5

    FilmArray BCID2 Control Panel M416

    Posted by MMQC on 11th Jun 2021

    FilmArray BCID2 Control Panel M416 is intended for use as an external quality control to monitor the performance of in vitro laboratory nucleic acid testing procedures for the qualitative detection of Gram positive and Gram negative bacteria, antimicrobial resistance genes and yeast pathogens on the BioFire® Blood Culture Identification 2 (BCID2) Panel on the BioFire FilmArray® systems.

View AllClose