Cat α-1-Acid Glycoprotein (AGP) SPARCL™ Assay | AGP-SP-8

(No reviews yet) Write a Review
SKU:
198-AGP-SP-8
Availability:
One Week Delivery
Size:
96 Wells
Select Currency //702.00

 Select your currency from the header

Description

Cat α-1-Acid Glycoprotein (AGP) SPARCL™ ASSAY | AGP-SP-8 from Gentaur SPARCL is in Stock.

INTRODUCTION

AGP is a highly glycosylated ~40 kDa acute phase protein that is elevated in cat serum due to injury, infection or disease. Kajikawa, et al. (ref 1) reported a 19-fold increase of AGP in serum from hospitalized cats and a 5.7-fold increase after injection of normal cats with lipopolysaccharide. Of the positive acute phase proteins investigated (AGP, SAA and CRP), AGP was the most responsive. More recently, Paltrinieri et.al., reported AGP to be a powerful discriminating biomarker for diagnosis of feline infectious peritonitis (ref 2). In studies at Life Diagnostics, we found AGP levels of 346±42 mg/ml in plasma from healthy cats.

PRINCIPLE OF THE ASSAY

The cat AGP SPARCL™1 (ref 3) assay uses two cat AGP-specific antibodies. One is conjugated to horseradish peroxidase (HRP), the other is conjugated to acridan, a chemiluminescent substrate. When the HRP and acridan conjugated antibodies bind to AGP they are brought into close proximity. With the addition of hydrogen peroxide, HRP catalyzes oxidation of proximal acridan molecules causing a flash of chemiluminescence. Acridan conjugated antibodies distant from HRP produce no signal. This principle allows the development of a homogeneous assay that allows rapid measurement of AGP concentrations.

The HRP and acridan conjugated antibodies provided with the kit are mixed with standards and diluted samples in wells of the 96-well SPARCL™ plate provided with the kit2. After incubation for 30 minutes on a shaker at 25°C and 150 rpm, the plate is placed into a luminometer. Trigger solution containing hydrogen peroxide is injected into each well and luminescence is immediately measured. The concentration of AGP is proportional to luminescence and is derived from a standard curve.

MATERIALS AND COMPONENTS

Materials provided with the kit:

• Anti-cat AGP HRP conjugate Store ≤ -70°C

• Anti-cat AGP acridan conjugate Store ≤ -70°C

• AGP stock Store ≤ -70°C

• Diluent; CSD50-1, 2 x 50 ml

• Trigger solution; TS7-1, 7 ml

• White SPARCL™ plate (12 x 8-well)

• Clear untreated 96-well plate

Materials required but not provided:

• Precision pipettes and tips

• Polypropylene microcentrifuge tubes

• Vortex mixer

• Plate incubator/shaker

• Luminometer capable of simultaneous injection/measurement

• Graphing software

STORAGE

Store the HRP conjugate, acridan conjugate and AGP stock at -70°C (they may be stored at -20°Cfor one week). The remainder of the kit should be stored at 2-8°C. The SPARCL™ plate should be kept in a sealed bag with desiccant and antioxidant. The kit will remain stable for at least six months from the date of purchase, provided that the components are stored as described above

GENERAL INSTRUCTIONS

1. Please take the time to completely read all instructions before starting your assay. Contact us if you need clarification.

2. All reagents used in the assay should be allowed to reach room temperature (25°C) before use.

3. It is important that standards and samples be added to the SPARCL™ plate quickly. If testing large numbers of samples, rather than pipetting standards and samples directly into the white SPARCL™ plate using a single channel pipettor, we recommend the following. First, pipette an excess volume of standards and samples into appropriate wells of the clear 96- well plate. Then use an 8- or 12-channel multipipettor to quickly and efficiently transfer 50 ml aliquots to the appropriate wells of the white SPARCL™ plate. The wells of the clear plate hold a maximum volume of 300 ml.

4. Follow the sequence of events below when running the assay.

View AllClose