LaunchWorks One-Step RT-qPCR Master Mix

LaunchWorks One-Step RT-qPCR Master Mix

Launchworks (blue) vs. Thermo Fisher (grey).

Detection of 1 copy of SARS CoV-2 E-gene target

LaunchWorks One-Step RT-qPCR Master Mix:
Sensitive, Reproducible Detection

The LaunchWorks One-Step RT-qPCR Master Mix was designed for sensitive and reproducible detection of RNA and/or DNA targets in a single multiplex RT-qPCR reaction. The 2X format was developed to guarantee simple reaction setup and robust performance. The Master Mix has been formulated and is manufactured in LaunchWorks’ ISO 13485, cGMP compliant facility, ensuring stringent production and quality control measures.

Features

• Ability to run multiplexed reactions
• Robust sensitivity for high and low-copy targets
• ISO 13485:2016 certified facility

• Built in tolerance to common clinical sample inhibitors
• Compatible with a range of RT-qPCR equipment
• Manufactured under cGMP conditions

 

Only three steps from sample prep (i.e. RNA extraction) to getting results from your RT-qPCR results:

1) reagent mixing 2) plate dispensing 3) RT-qPCR method running

Broad Dynamic Range

A master mix must be reliable across a dynamic range of copy numbers for any desired target. This is especially true in a clinical setting where pathogens may be present at low titers. Every lot of this 2X One-Step RT-qPCR Master Mix undergoes quality control performance testing across 6 magnitudes of SARS CoV-2 E-gene template RNA. The master mix is designed to use only a single assay protocol to test for either (or both) RNA and DNA and requires no passive dye.

Figure: Sensitive and reproducible detection across 6 magnitudes of SARS CoV-2 E-gene RNA template, testing down to 27 copies. Amplification plot using the 2X One-Step RT-PCR Master Mix, and the 2019-nCoV Primer Probe Panel (Charité/Berlin) available from IDT, with FAM probe detection.

High Sensitivity

Performance of LaunchWorks produced master mix is comparable to ThermoFisher’s 4X TaqPath 1-Step Multiplex Master Mix. As the copy number of E-gene present in the assay decreases, the LaunchWorks master mix amplification curve plateau reads stronger than the Thermo Fisher master mix.

Figure: Detection of 1 copy of SARS CoV-2 E-gene target in extracted reference material - Launchworks 2X One-Step RT-PCR Master Mix (blue) vs. Thermo Fisher 4X TaqPath 1-Step Multiplex Master Mix (grey).

Consistent Performance

Strict lot-to-lot quality control for critical components ensures consistent performance of the LaunchWorks 2X One-Step RTqPCR Master Mix.

Figure: Sensitive and reproducible detection across 6 magnitudes of SARS CoV-2 E-gene RNA template, testing down to 27 copies. Amplification plot using the 2X One-Step RT-PCR Master Mix, and the 2019-nCoV Primer Probe Panel (Charité/Berlin) available from IDT, with FAM probe detection.

Clinical Performance

Proven performance of the LaunchWorks 2X One-Step RT- qPCR Master Mix in direct comparison to the Thermo Fisher 4X TaqPath 1-Step Multiplex Master Mix. During this testing, the LaunchWorks master mix performed equal or better than the Thermo Fisher master mix.

Figure: Clinical data across 10 randomly chosen patients comparing the Launchworks 2X One-Step RT-qPCR Master Mix (green) and Thermo Fisher 4X TaqPath 1-Step Multiplex Master Mix (grey).1

1 Dr. Raymond Tellier and Dipchan Nancoo, Optilab MUHC, Glen Site, June 2020

Broad Instrument Compatibility

The LaunchWorks 2X One-Step RT-qPCR Master Mix has been shown to perform across a wide range of real-time PCR systems. These systems include (but are not limited to) Applied Biosystems, BioRad CFX and Roche Lightcycler PCR platforms.

High-Quality Enzymes

The master mix is made up of 4 highly specific and active enzymes:
1) Reverse Transcriptase (RT) 2) RNAse Inhibitor (RI) 3) Taq DNA Polymerase (Taq) 4) Uracil-DNA Glycosylase (UDG)

Specifications

Product Name: Launchworks 2X One-Step RT-qPCR Master Mix (No ROX)

Components: 2X mix requiring no passive dye. 10 x 1 mL microtubes (100 reactions per tube)

Shelf Life: 12 months

Storage Temp: -20°C or below

Assay Name/Specification (min release criteria): Launchworks 2X One-Step RT-qPCR Master Mix (No ROX) is functionally tested in One-Step RTqPCR with SARS CoV-2 E-gene RNA template, resulting in a standard curve across a dynamic range of 6 orders of magnitude

Individual Product Component Testing: Quality Control Tests including activity testing protocols are performed for each component included in the Launchworks 2X One-Step RT-qPCR Master Mix (No ROX) and meet the designated specifications of RNAse, DNAse and Protease Free

Ordering Information

Please contact us at (718) 513 2983 for US or (32) 016 589 045 for Europe or info@gentaur.com for a quote or to learn more!
For Research Use Only.