Mini Samples ELISA Kit for Monocyte Chemotactic Protein 1 (MCP1) | MEA087Mu

(No reviews yet) Write a Review
SKU:
MEA087Mu
Availability:
In Stock
Organism Species:
Mus musculus (Mouse)
Sample Type:
Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Detection Range:
10-640pg/mL
Request pricing by email to info@gentaur.com

 Select your currency from the header

Description

Mini Samples ELISA Kit for Monocyte Chemotactic Protein 1 (MCP1) | MEA087Mu

Specificity

This assay has high sensitivity and excellent specificity for detection of Mini Samples Monocyte Chemotactic Protein 1 (MCP1).
No significant cross-reactivity or interference between Mini Samples Monocyte Chemotactic Protein 1 (MCP1) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of recombinant Mini Samples Monocyte Chemotactic Protein 1 (MCP1) and the recovery rates were calculated by comparing the measured value to the expected amount of Mini Samples Monocyte Chemotactic Protein 1 (MCP1) in samples.

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Mini Samples Monocyte Chemotactic Protein 1 (MCP1) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Mini Samples Monocyte Chemotactic Protein 1 (MCP1) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Mini Samples Monocyte Chemotactic Protein 1 (MCP1) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

Reagents and materials provided

Assay procedure summary

1. Prepare all reagents, samples and standards;
2. Add 25µL standard or sample to each well. Incubate 1 hour at 37°C;
3. Aspirate and add 25µL prepared Detection Reagent A. Incubate 1 hour at 37°C;
4. Aspirate and wash 3 times;
5. Add 25µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;
6. Aspirate and wash 5 times;
7. Add 25µL Substrate Solution. Incubate 10-20 minutes at 37°C;
8. Add 20µL Stop Solution. Read at 450nm immediately.

View AllClose

0 Reviews

View AllClose